What is in your glass?
Pour a glass of cold water and let it sit for a while. What you see tells you which form of iron or manganese you are dealing with, and that changes the treatment. Start with Charlottesville well water testing to identify exactly which form you have.
Dissolved iron or manganese
Water looks clear from the tap, then rust or black particles form and settle as it meets air.
Particulate iron or manganese
Water comes out red, yellow, rusty or brownish-black because the metal is already oxidized.
Most of the time, the metals come from minerals in the rock and soil that groundwater dissolves on its way to your well. That is why levels can differ a lot from one property to the next, and why a neighbor's results do not tell you much about yours. Corroding iron or galvanized steel pipes can also add iron to your water, so the source is not always the well itself. A test that compares water straight from the pressure tank with water from a faucet can help narrow that down.
Read the stain
| What you notice | Likely cause |
|---|---|
| Reddish-brown stains | Iron |
| Brownish-black stains | Manganese |
| Red-brown slime in the toilet tank | Iron bacteria |
| Black-brown slime where water stands | Manganese bacteria |
| Black sludge in tea or coffee | Iron or manganese reacting with tannins |
| Dropping water pressure over time | Buildup in pipes, pressure tank or water heater |
One warning from Virginia Cooperative Extension: chlorine bleach and alkaline cleaners can actually make iron and manganese stains worse.
The numbers that matter
0.3 mg/L
Iron
EPA secondary standard
0.05 mg/L
Manganese
EPA secondary standard
0.3 mg/L
Manganese
EPA lifetime health advisory
The secondary standards are about stains, taste and color, not health. Even levels below them can still stain. Iron is rarely a health concern, though people with hemochromatosis may be more sensitive and should ask their doctor. Manganese gets more attention, because the EPA has set a lifetime health advisory for it at 0.3 mg/L. If your manganese result is near that number, treat it as more than a cosmetic issue.
Match the treatment to your level
Virginia Tech's guidance sorts treatment by the combined amount of iron and manganese in your water. Add your two lab results together, then find your range. For example, a report showing 2.5 mg/L of iron and 0.4 mg/L of manganese gives a combined level of 2.9 mg/L, which falls in the range a softener can usually handle. A report showing 7 mg/L of iron and 1 mg/L of manganese adds up to 8 mg/L, which points toward aeration with filtration or an oxidizing filter.
Which treatment fits your combined level
Treatment by level
Ion exchange water softener
Usually handles low levels, but iron uses up softening capacity, so it regenerates more often. Check the manufacturer's maximum iron rating, and expect extra sodium in the water. See our water softener guide.
Aeration followed by filtration
Air oxidizes the metals into particles that a filter catches. Manganese needs more time and oxygen than iron. Not a good fit if iron bacteria or organic iron are present, since they clog the filter.
Oxidizing filter
Usually manganese greensand or a coated zeolite media. It treats both dissolved and particulate forms and needs routine backwashing.
Chemical oxidation and filtration
Chlorine, potassium permanganate or hydrogen peroxide oxidizes the metals before a sand filter removes them. Rare in homes, but useful when iron bacteria or organic matter are involved.
You may also see phosphate feeders sold for iron. Phosphate does not remove iron or manganese, it only keeps them dissolved, and Virginia Tech does not recommend it here. Phosphate going down the drain can feed algae in streams, and Virginia limits it in cleaning products.
Slime is a different problem
Some bacteria feed on iron and manganese. They are not a health risk, but they leave red-brown or black-brown slime in toilet tanks and anywhere water sits, and over time they can clog the system. A filter alone will not fix this. Shock chlorination of the well controls the bacteria, and a licensed well driller is the right person for that job. If the slime returns, chemical oxidation with filtration is the method built for it.
Mistakes that cost well owners money
- 1
Buying a softener for high iron
Past the manufacturer's limit, iron clogs the resin and the softener fails early.
- 2
Treating iron alone
Equipment should be chosen alongside fixes for other problems on your report, such as low pH, hardness or bacteria. Our filtration guide covers how those systems fit together.
- 3
Skipping the lab test
You need actual iron and manganese numbers, plus a sense of which form is present, to size anything correctly.
- 4
Forgetting maintenance
Backwashing schedules depend on how much iron you have and how much water you use.
Equipment should be chosen alongside fixes for other problems on your report. See our filtration guide for how those systems fit together.
Questions to ask before you buy
Once you have numbers, bring them to two or three suppliers, as Virginia Tech recommends, and ask each one the same questions:
- What combined iron and manganese level is this unit rated for, and how close is my water to that limit?
- Will it handle iron bacteria if they show up later?
- How often does it need backwashing, recharging or new media, and what does that cost each year?
- Is the equipment certified by an independent third party such as NSF?
- How does it fit with anything else my water needs, like a neutralizer, softener or UV light?
A good installer will answer from your lab report, not from a test strip run at your kitchen sink.
Getting tested near Charlottesville
Iron and manganese are most accurately measured by a certified lab. The Virginia Household Water Quality Program includes both in its $70 sample kit, along with pH, hardness, bacteria and more, during scheduled clinics with results in about four weeks. A certified lab can run the same tests on your timeline. Once treatment is installed, testing before and after the equipment each year confirms it is doing its job, which is what our annual testing plan is for.
Iron and manganese FAQ
Is iron in well water harmful?+
For most people, no. Iron in well water is mainly a nuisance that causes stains and a metallic taste, which is why the EPA treats it under its secondary standards. People with hemochromatosis, a condition that causes excess iron in the body, may be more sensitive and should talk to their doctor. Manganese is different: the EPA has a health advisory for it at 0.3 mg/L.
How do I get rid of iron in my well water?+
Start with a lab test that measures iron and manganese together. Up to about 5 mg/L combined, a water softener can usually handle it. Between 5 and 10 mg/L, aeration followed by filtration works. Oxidizing filters handle up to about 15 mg/L, and chemical oxidation with filtration is used above 10 mg/L or when iron bacteria are present.
What causes black stains from well water?+
Brownish-black or black stains usually point to manganese, while reddish-brown stains point to iron. Black slime in a toilet tank can also mean manganese bacteria, which feed on the metal. A lab test confirms which one you have, and shock chlorination controls the bacteria if they are present.
Why does my well water turn orange after sitting?+
Your well likely has dissolved iron. It looks clear coming out of the tap, then reacts with air and turns into rust-colored particles that settle to the bottom of the glass. This form of iron can be treated with a softener at low levels or an oxidizing filter at higher levels, depending on your test results.