Shock & UV guide

Well Water Disinfection in Charlottesville, VA

A positive bacteria test, a flooded wellhead, or a pump that just came out of the ground for repairs all lead to the same question: how do you get the well clean again? Here is how disinfection works for private wells in Charlottesville and Albemarle County, and how to tell whether you need a one-time fix or something permanent.

  • Shock chlorination, step by step
  • UV vs continuous chlorination
  • Retest to confirm it worked

Get your free disinfection quote

Tell us about your well, your bacteria result, or your repair, and we will recommend the right disinfection plan and retest.

The two options

Two kinds of disinfection

One-time

Shock chlorination

A strong chlorine solution is circulated through the well and every pipe in the house, left to sit, then flushed out. It kills bacteria that are already in the system.

Ongoing

Continuous disinfection

Equipment such as an ultraviolet light or a chlorine feeder treats water every time you use it. It's the answer when bacteria keep coming back.

Most wells start with shock chlorination. Continuous disinfection comes in only when retests keep failing, or when the source of contamination can't be removed. Our Charlottesville well water testing plan tells you which path you need.

The trigger

When a well needs to be shocked

According to Virginia Cooperative Extension, shock chlorination is required after a new well is built, and recommended in these situations:

  • Positive testTotal coliform shows up in a water sample
  • RepairsAny maintenance or repair on the well, pump or plumbing
  • FloodingFloodwater reached the well or its surroundings
  • Obvious exposureA clear contamination source appears near the well

The repair point surprises people. Simply pulling a pump out of the well and setting it on the ground is enough to introduce bacteria, so any good well contractor should disinfect the system before they leave.

Fix the source

Fix the cause first

Shock chlorination kills the bacteria that are in the water today. It doesn't stop new bacteria from getting in. If a loose cap, a cracked casing, water pooling at the wellhead, or a failing septic system is letting contamination in, the problem will come back within weeks. That's why a quick well inspection belongs before, or at least alongside, any disinfection.

The process

How shock chlorination works

From start to clean result

PrepPower off, cap off, dose mixed
CirculateChlorine through well and every tap
Let stand12 to 24 hours, no water use
Flush and waitRun taps clear, retest in 1 to 2 weeks
Based on Virginia Cooperative Extension publication 442-663.
Step by step

The shock chlorination steps

  1. 1

    Clean and open

    Power to the pump goes off, debris is cleared from the wellhead and the cap comes off. If the cap isn't a sealed, sanitary cap, this is the time to replace it.

  2. 2

    Calculate, mix and pour

    The dose depends on the well's diameter and the depth of water in it. For wells built after 1992, both numbers are on the well completion report at the health department.

  3. 3

    Circulate

    Water runs from a hose back into the well until it smells strongly of chlorine, washing down the inside of the casing. Then every faucet, hot and cold, is opened until it smells of chlorine, and each toilet is flushed.

  4. 4

    Close and let stand

    The pump goes off, the cap goes back on, and the chlorine sits in the system for 12 to 24 hours. No water gets used during that time.

  5. 5

    Flush

    Outdoor faucets run first, onto gravel or bare ground, then indoor taps until the chlorine smell is gone. Keep as much of that water as possible out of the septic system.

  6. 6

    Retest

    Wait one to two weeks, then test again for total coliform and E. coli. If bacteria are still there, continuous disinfection may be needed.

Safety first

Before anyone starts

  • Have 12 to 24 hours of bottled water on hand for drinking and cooking.
  • Concentrated chlorine calls for goggles, rubber gloves, boots and good ventilation.
  • The pump is electric. The breaker stays off whenever the cap is off.
  • Strong chlorine can damage pressure tanks, softeners and filters. Check each manufacturer's instructions for bypassing or protecting them.
  • Older dosing charts assume 5.25% household bleach. Many bleaches sold today are stronger, so check the label before using any chart.
Flushing tips

Two flushing tips

The water heater is the hardest part to clear, so draining it helps, with the power or gas turned off first. And if you want to be sure the chlorine is gone, a free chlorine test kit from a home improvement store will tell you.

Springs and cisterns

Springs and cisterns

Some rural properties around Charlottesville still draw from a spring or store water in a cistern, and these need disinfecting too. Springs are especially prone to bacteria because they usually sit in surface drainage paths. Virginia Tech's method starts with scrubbing the inside of the spring box or cistern with a strong solution of half a gallon of unscented bleach in 5 gallons of clean water, sealing any cracks while it's open. The dose is then based on the stored volume: length times width times water depth in feet, times 7.5 for gallons, plus 110 gallons for the house plumbing. The publication calls for 3 pints of 5.25% bleach or 4 ounces of calcium hypochlorite per 100 gallons, followed by the same circulate, stand, flush and retest steps.

For wells, Virginia Tech suggests hiring a licensed well driller to do the shock chlorination. A capable homeowner can do it, but the driller brings the right equipment, can measure an older well that has no records, and can spot the problem that let bacteria in.

When shock isn't enough

When shocking isn't enough

If coliform keeps returning after repairs and repeated shock treatments, it's time for continuous disinfection. Here's how the main options compare, based on Virginia Tech's household water treatment guidance:

MethodWhat it does wellLimits to know
Ultraviolet (UV) lightKills bacteria and viruses with no added chemicalsNeeds clear water; less effective on Giardia and Cryptosporidium; lamp must be replaced on schedule
Continuous chlorinationKills bacteria and some viruses; also oxidizes iron, manganese and sulfurWon't kill Giardia or Cryptosporidium; dose depends on pH, temperature and contact time; may need filters after
OzonationAnother continuous option listed by Virginia Tech's programBest chosen with a water treatment professional
BoilingDisinfects small amounts for drinking and cookingNeeds a rolling boil for at least one minute; not practical for a whole house

UV has one more condition worth knowing. If a well shows more than 1,000 total coliforms or more than 100 fecal coliforms per 100 mL, Virginia Tech recommends a different disinfection method. Because cloudy water blocks the light, UV is usually the last stage in a treatment setup, after any sediment, iron or softening equipment. Our filtration guide shows how those stages fit together.

Confirm it worked

Prove it worked

Disinfection is only finished when a lab says so. A bacteria and E. coli test one to two weeks after shocking tells you whether the well is clean. Avoid sampling right after the flush, since leftover chlorine can produce a clean result that doesn't last. After that, test at least once a year and after any future repair, flood or change in your water.

Retest 1 to 2 weeks after shocking Certified bacteria retest
Common questions

Well disinfection questions

How long after shocking a well can you drink the water?+

The chlorine needs to sit in the system for 12 to 24 hours, and then every faucet is flushed until the chlorine smell is gone. That makes the water usable again, but it doesn't prove it's safe. Virginia Tech recommends retesting for bacteria one to two weeks later. If E. coli was the original problem, keep using bottled water or boil drinking water for at least one minute until the retest comes back clean.

How often should you shock chlorinate a well?+

Not on a fixed schedule. Shock chlorination is required after a new well is built and recommended after a positive coliform test, after any repair or maintenance on the well or plumbing, and after flooding. If you find yourself shocking the same well over and over, the contamination source hasn't been fixed, and continuous disinfection may be needed.

Is UV or chlorine better for well water?+

Each has strengths. UV adds no chemicals and works well on bacteria and viruses, but it needs clear water and is less effective against Giardia and Cryptosporidium. Continuous chlorination also oxidizes iron, manganese and hydrogen sulfide, but it doesn't kill Giardia or Cryptosporidium and often needs filters afterward. Your test results and other water problems decide which fits.

Can I shock chlorinate my own well?+

An experienced do-it-yourselfer can, but Virginia Tech suggests hiring a licensed well driller. The job involves concentrated chlorine, an electric pump, and a dose that depends on the well's diameter and water depth. A driller can also spot the cap, casing or grading problem that let bacteria in, which shock chlorination alone won't fix.

Confirm your well is clean

Certified bacteria retesting for Charlottesville and Albemarle County wells after disinfection, repairs or flooding.

Get a free quote
Charlottesville & Albemarle County Retest to confirm